Description
The GSM-AUTO is a wireless remote control on/off switch that connects to the GSM mobile phone network.
It has 2 independent relay switches, which can be programmed to switch on or off for a set length of time whenever the GSM-AUTO is called. The GSM-AUTO recognises an authorised telephone number calling it and acts on the call without answering. Therefore there are no call charges when calling it.
The relay switches can also be temporarily or permanently switched on or off by sending the GSM-AUTO a text message command.
| Specification | Value |
|---|---|
| Operating voltage | 12 volts DC |
| Operating current | Maximum 500 mA, typically 55 mA |
| Relay contacts | 2 x normally open and normally closed contacts, maximum switching capacity 10 amps @ 230 V AC per relay |
| GSM frequency MHz | GSM-850, GSM-900, GSM-1800, GSM-1900 |
| Humidity | Less than 80 % RH |
| Operating temperature | -20 °C to 55 °C |
| Physical size | 130 x 100 x 50 mm |
| Protection | IP65 |
| Approvals | CE |
Requirements
The GSM-AUTO requires a 12 volt DC power supply that can provide a minimum current of 500 mA; typical current consumption is 50 mA.
An active mobile phone SIM card with enough credit to send confirmation text messages when programming the GSM-AUTO.
Preparing the SIM card
All new SIM cards have to be registered with the network provider before they can be used, usually by calling the network provider or registering on its website. Please refer to the instructions supplied with your SIM card.
During registration a confirmation code or text message is usually sent to the SIM card's telephone number. To read and react to the message you will need to insert the SIM card into an unlocked mobile phone.
After registering the SIM card, make sure there is enough credit on the card for the programming confirmation texts to be sent from the GSM-AUTO.
You MUST make sure the PIN request is disabled on the SIM card before inserting it into the GSM-AUTO. If you do not disable the PIN request the GSM-AUTO will not work. If the PIN request is not disabled and the unit is switched on more than 3 times, you will have to reset the PIN using the PUK code, which you get from the service provider.
To check the PIN request status of your SIM card, place the card in an unlocked mobile phone and switch the phone on. If you can make calls without entering a PIN number, the PIN request is disabled. If a PIN number is requested, refer to the instructions supplied with the SIM card, then look through the phone's options for 'disable PIN request' and disable it.
You MUST disable any voicemail that is set up on the SIM card. Ask your network operator how to do this; the codes differ between networks and countries.
The SIM card is now ready to use.
If you use a pay-as-you-go (PAYG) SIM card, we recommend choosing automatic top-up when the card's credit falls below a certain limit. Contact your network provider or visit its website for details.
Most but not all PAYG SIM cards will be deactivated by the network if they are not used to make an outgoing voice call or send a text message within a specific period. To prevent this, simply send the GSM-AUTO a text command; it will reply by text message. Do this once a month to keep the SIM card active.
Installation

Insert the SIM card: to open the SIM card carrier, gently push the button next to it, insert the SIM card and carefully close the carrier.
Connect a 12 volt DC power supply to terminals 1 and 2, making sure positive is connected to terminal 1. Switch on the power supply. The red power LED will light, showing power is present. The blue network LED will flash quickly at first; once logged onto the network it will flash more slowly, about once every 3 to 4 seconds.
It is recommended that the GSM-AUTO is programmed to operate as required before final installation.
Connection details
Terminal 1: +12 V DC. Terminal 2: negative. Relay 2: terminal 3 common (C), terminal 4 normally closed (NC), terminal 5 normally open (NO). Relay 1: terminal 6 normally closed (NC), terminal 7 normally open (NO), terminal 8 common (C).
If you are unsure how to connect the device you wish to control, refer to a qualified person.
Example connections
Server 1 (main) connected to relay 1: when the GSM-AUTO is activated the relay contact switches from the NC position to the NO position, breaking the circuit and resetting the server. Server 2 (backup) connected to relay 2: when the GSM-AUTO is activated the relay contact switches from the NC position to the NO position, switching on the server.
A heater connected to relay 2 and a light to relay 1: when the GSM-AUTO is activated the relay contact switches from the NC position to the NO position, making the circuit, and the heater and light are switched on.
Both examples are drawn as diagrams on the wiring examples page.
Default settings and programming
The default settings are open access mode, in which a call from any telephone number activates the GSM-AUTO. When the GSM-AUTO is called, relay 1 switches on for 2 seconds, and 2 seconds later relay 2 switches on for 2 seconds. The default password is 123456.
The GSM-AUTO is programmed by sending it SMS text commands to the telephone number of the SIM card installed in it. The password command must prefix all SMS text commands. It is recommended that the default password is changed.
Remember that all SMS text commands must always be sent in CAPITAL LETTERS. Do NOT add spaces or any other characters.
Programming commands
#PWD: password
This command must always prefix any SMS text command sent to the unit: #PWDXXXXXX, where XXXXXX is the six-digit password. The unit's default password is 123456, so at first #PWD123456 is entered before the command. When you change the password, you prefix all commands with the new password.
#CAP: changing the password
To change the password from the default 123456 to 121212, send the following text message to the unit. Please make a note of your new password: if you lose or forget it you will not be able to access the unit. The examples below use 121212.
#PWD123456#CAP121212#CAP121212Change the password to 121212 · reply CAP:121212#CSQ: check the signal strength
This shows the GSM network signal strength where the unit is, in the range 0 to 31. A minimum of 5 is required. If it is below 5, an external antenna is advised.
#PWD121212#CSQ?Check the signal strength · reply CSQ<6>#TEL: administrator list
This command adds or removes the administrator numbers that receive text messages from the unit when the relays are switched on or off with the #RLY and #RLOP commands. If you want confirmation texts, you must enter your telephone number in the administrator list.
Up to 8 administrator numbers can be in the list, and each can have up to 16 digits. If an administrator wants to receive text messages while abroad, prefix the number with the country code, for example a UK number as +447700900123.
#PWD121212#TEL1=07700900123Add 07700900123 to the administrator list · reply TEL1=07700900123#PWD121212#TEL?Check all administrator numbers · reply TEL1:07700900123 TEL2: TEL3:#RERN: administrator alerts on or off
This enables, disables and checks the administrator positions that receive text alerts. To let only the first administrator receive alerts, send the command below: 1 enables the first position and 0 (zero) disables the other 7 positions.
#PWD121212#RERN=10000000Only administrator 1 receives alerts · reply RERN:10000000#PWD121212#RER?Check the RERN status · reply RERN:10000000#WHL: white list
This adds the authorised telephone numbers that can activate the unit. By default the unit is in open access mode and is activated by a call from any number. When the authorised numbers have been added, set the unit to secure access mode with #ACM2.
Only enter the last 8 digits. This is the first number in the white list; number 2 is sent as #WHL002= and so on, up to a maximum of 500 numbers.
#PWD121212#WHL001=00900123Add 07700900123 in position 1 · reply WHL001:00900123#PWD121212#WHL001?Check the number in position 001 · reply WHL001:00900123#PWD121212#WHL001DErase the number in position 001 · reply WHL001-OK#ACM: security access mode
This enables secure access mode, so only the numbers in the white list can activate the unit. ACM0 switches secure access off and open access on.
#PWD121212#ACM2Secure access on · reply ACM-ON#PWD121212#ACM0Secure access off · reply ACM-OFF#GOT: relay on time
This sets the relay on times when the unit is called. The maximum time is 65,535 seconds. The first digit after GOT is the relay number, then the time in seconds in 5-digit format. Setting the GOT1 or GOT2 time to 00000 prevents that relay activating when the unit is called.
#PWD121212#GOT1=00900Relay 1 on for 15 minutes when called · reply GOT1:00900#PWD121212#GOT2=00600Relay 2 on for 10 minutes when called · reply GOT2:00600#GOTS: delay before relay 2
This sets a delay before relay 2 switches on after a call, in seconds in 5-digit format. Setting GOTS to 00000 prevents relay 2 switching on. To check the relay on and delay times, send #GOT?.
#PWD121212#GOTS=000055 second delay before relay 2 · reply GOTS:00005#PWD121212#GOT?Check relay and delay times · reply GOT1: 00900 GOT2: 00600 GOTS: 00005#RLY: temporary switching on the relays
This switches the relays on for up to 65,000 seconds and sends confirmation texts when they switch on and off. It does not affect the #GOT1 or #GOT2 settings. Confirmation text messages are only sent to numbers in the administrator list.
#PWD121212#RLY1=00060Relay 1 on for 60 seconds · reply RLY1=00060 then RELY1-OFF#PWD121212#RLY2=00005Relay 2 on for 5 seconds · reply RLY2=00005 then RELY2-OFF#RLOP: switching the relays on and off
This switches the relays on and off and sends confirmation texts. It does not affect the #GOT1 or #GOT2 settings. Confirmation texts are only sent to numbers in the administrator list. Use #RLOP2=1 and #RLOP2=0 for relay 2. A 'RLOP1 Busy' message means the relay is already active from a previous command.
#PWD121212#RLOP1=1Relay 1 on · reply RLOP1=ON#PWD121212#RLOP1=0Relay 1 off · reply RLOP1=OFF then RELY1-OFF#RLY?: checking the status of the relays
#PWD121212#RLY?Relay status · reply RELAY1=00000 RELAY2=00000 RLOP1:OFF RLOP2:OFF*REST#: resetting the unit
This resets the unit to the default settings. The password prefix is not required. After REST-OK the unit is back to its default settings and the password reverts to 123456.
*REST#121212Reset to default settings · reply REST-OKProgramming examples
Controlling a heating system
The simplest way is to wire terminals 7 and 8 on the GSM-AUTO to the terminals on your heating programmer that switch it on. When away from home, set the heating programmer to off. You can program the unit to switch the heating on for, say, 2 hours when you call it.
Add the telephone numbers you want to use to activate the unit, only the last 8 digits. Repeat for every number, incrementing the WHL position by one each time: WHL002=, WHL003= and so on. Then switch on secure access so only the numbers in the white list can activate the unit, and set the relay on time to 2 hours.
#PWD123456#WHL001=00900123Step 1: add a number to the white list · reply WHL001:00900123#PWD123456#ACM2Step 2: secure access on · reply ACM-ON#PWD123456#GOT1=07200Step 3: relay on for 2 hours · reply GOT1:07200Controlling an automatic electric gate
Wire terminals 7 and 8 on the GSM-AUTO to the 'start' push button terminals of the gate control panel. Follow steps 1 and 2 above, then set the relay activation time to 1 second. Do not use the gate control panel's auxiliary power supply to power the GSM-AUTO; use a separate power supply.
#PWD123456#GOT1=00001Relay pulse of 1 second · reply GOT1:00001Ad hoc control of any device using only text messages
Switch on secure access mode and do not enter any numbers in the white list, so calls do nothing. Add your telephone number to the administrator list and enable it to receive confirmation texts. Then switch the relays on for a set time, or on and off.
#PWD123456#ACM2Secure access, empty white list · reply ACM-ON#PWD123456#TEL1=01800900123Your number as administrator 1 · reply TEL1=01800900123#PWD123456#RERN10000000Enable confirmation texts for administrator 1 · reply RERN:10000000#PWD123456#RLY1=00060Relay 1 on for 60 seconds · reply RLY1=00060#PWD123456#RLOP1=1Relay 1 on until switched off · reply RLOP1=ONTroubleshooting
| Problem | What to do |
|---|---|
| 1. Red power LED not alight | Make sure your DC power supply is connected correctly, positive (+) to terminal 1 and negative (-) to terminal 2. Check that 12 volts is present with a voltmeter. |
| 2. Blue network LED flashing every second, not every 3 seconds | Make sure your SIM card has been activated and the PIN request disabled. In a low signal area consider an external GSM antenna or another network provider. Also check that a 2G network is still running where the unit is. |
| 3. No confirmation texts when using #RLY or #RLOP | Make sure your number is in the administrator list and that texts to your number are enabled. See #TEL and #RERN. |
| 4. No text messages at all when first programming the unit | Make sure the unit is on the GSM network: the blue LED should flash once every 3 seconds (see 2). Make sure the SIM card has credit. |
| 5. Relays switched on with #RLY or #RLOP switch off when the unit is called | This is the way the unit operates. Switch on secure access mode #ACM2 so only numbers in the white list can activate the unit. |
| 6. The unit occasionally activates by itself | Network operators often make marketing calls to their subscribers. Switch on secure access mode #ACM2 so only numbers in the white list can activate the unit. |
| 7. Worked for several months, now ignores calls and text commands | Most but not all PAYG SIM cards are deactivated if no outgoing call or text is made within a set period. Send the GSM-AUTO a text command once a month; it replies and the SIM card stays active. |
| 8. No confirmation text after calling the unit | The unit only sends relay status messages in response to the #RLOP and #RLY commands. |