GSM-AUTO owners Manual (PDF) Help Contact
Use

Switch on an engine pre-heater with a phone call

Call the switch on your way out and the engine is warm when you get to the car. The switch closes the pre-heater's start contact for the time you set, then lets it go.

Engine pre-heater timer input wired to relay 1, terminals 7 (NO) and 8 (C)1+2-3C4NC5NO6NC7NO8C12 V DCRELAY 2RELAY 1PRE-HEATER TIMERsupplysupplyNO
Engine pre-heater timer input wired to relay 1, terminals 7 (NO) and 8 (C). Relays drawn at rest (off).

Pre-heating with a phone call

The GSM-AUTO can be connected to the engine pre-heater timer control, or on a new installation it may be possible to connect it directly to the pre-heater, saving the cost of a timer unit. When the switch is called it turns on the engine pre-heater for a preset length of time between 1 second and 18 hours. The heater can also be switched on or off by sending the switch a text message.

This suits cars, vans and trucks parked away from the house, fleets on a yard, and anyone who leaves at irregular times. A fixed timer works when you leave at the same hour every day. A call works when you decide in the morning.

Two ways to wire it

To the pre-heater timer or remote input

Many fuel-fired and electric pre-heaters have a timer or remote start input that expects a switched contact. Wire relay 1 terminals 7 (NO) and 8 (C) to that input. The relay then does the same job as pressing the start button on the timer, and the heater's own safety and run-time logic stays in charge. This is the cleanest way and the one to try first.

Straight to a mains block heater

A mains-powered block or coolant heater can be switched directly through the relay contacts if its current is within the 10 amp at 230 volts rating. Heaters near that limit, or on long outdoor cables, belong on a contactor whose coil is switched by the relay. Mains wiring in a garage or outdoors needs proper enclosures, an RCD and, in most places, an electrician.

Safety. If you are unsure how to connect the device you wish to control, refer to a qualified person.

Example settings

Replace 121212 with your own password. The white list takes the last 8 digits of each phone number that may start the heater.

#PWD121212#WHL001=00900123Add your phone to the white list, position 001 · reply WHL001:00900123
#PWD121212#ACM2Only white-listed numbers can start the heater · reply ACM-ON
#PWD121212#GOT1=07200Relay 1 on for 2 hours after each call · reply GOT1:07200
#PWD121212#GOT2=00000Relay 2 does nothing on a call · reply GOT2:00000

Setting it up step by step

  1. Prepare the SIMRegister it, check the credit, switch off the PIN request and voicemail in a phone first.
  2. Program on the benchPower the switch from 12 V, change the password and send the commands above. Check each reply.
  3. Check the signal in the garageSend #CSQ? where the switch will be mounted. Below 5, use an external antenna through the SMA socket.
  4. Wire and testConnect terminals 7 and 8 to the timer input, call the switch and watch the heater start.

How long to run it

Two hours is the time used in the manual's heating example and a sensible start, but the right time depends on the heater and the cold. Follow the heater maker's guidance on run times and battery drain for fuel-fired heaters. If you sometimes need a different time, send #RLY1 with that time instead of calling; it does not change the setting used for calls.

Power for the switch itself: a vehicle installation has to supply a steady 12 volts. The switch draws about 50 mA while it waits, which adds up on a battery that is not being charged, so on a car that stands for weeks a mains-fed 12 V supply in the garage is the safer choice.

#PWD121212#RLY1=03600Just this once: heater on for 1 hour · reply RLY1=03600

Questions

Can I switch the heater off early?

Yes. Send #PWD121212#RLOP1=0 and relay 1 drops out. You get RLOP1=OFF followed by RELY1-OFF if your number is in the administrator list.

Will a call from my partner's phone work?

Only if their number is on the white list. Add it with the next free position, for example #PWD121212#WHL002= followed by the last 8 digits.

Does it work on a 12 V or 24 V truck supply?

The GSM-AUTO needs 12 volts DC. On a 24 V vehicle you need a suitable 24 to 12 V converter.