Rules for every command
- Start every command with #PWD and the six-digit password. The default is 123456; the examples below use 121212 after it has been changed
- Use capital letters only, and do not add spaces or any other characters
- Times are in seconds and always five digits: 00060 is one minute, 07200 is two hours
- Relay 1 is 1 in a command, relay 2 is 2
- Confirmation texts for relay switching go only to numbers in the administrator list
Password and signal
#PWD: password
This must always come first in any text command. #PWDXXXXXX, where XXXXXX is the six-digit password. The default password is 123456, so at first #PWD123456 goes in front of every command. Once you change the password, use the new one.
#CAP: change the password
Send the new password twice. Make a note of it: if you lose or forget the password you will not be able to access the unit.
#PWD123456#CAP121212#CAP121212Change the password from 123456 to 121212 · reply CAP:121212#CSQ: signal strength
Reports the GSM signal at the switch on a scale of 0 to 31. A minimum of 5 is required; below 5, use an external antenna.
#PWD121212#CSQ?Ask for the signal strength · reply CSQ<6>Administrators and white list
#TEL: administrator list
Administrators are the numbers that receive texts when the relays are switched on or off with #RLY and #RLOP. Up to 8 numbers of up to 16 digits. If an administrator wants texts while abroad, enter the number with its country code, for example +447700900123.
#PWD121212#TEL1=07700900123Put 07700900123 in administrator position 1 · reply TEL1=07700900123#PWD121212#TEL?List all administrator numbers · reply TEL1:07700900123 TEL2: TEL3:#RERN: which administrators get texts
Eight digits, one per administrator position: 1 enables that position, 0 disables it. The manual writes the command with an equals sign on its command page and without it in its examples; both forms appear below as printed. Check the status with #RER?.
#PWD121212#RERN=10000000Only administrator 1 receives texts · reply RERN:10000000#PWD121212#RERN10000000Same setting, as written in the manual's examples · reply RERN:10000000#PWD121212#RER?Check which positions are enabled · reply RERN:10000000#WHL: white list
The numbers allowed to activate the switch by calling it. Enter only the last 8 digits of each number. Positions run from 001 to 500. After adding the numbers, switch on secure access with #ACM2.
#PWD121212#WHL001=00900123Add 07700900123 in position 001 · reply WHL001:00900123#PWD121212#WHL001?Check the number in position 001 · reply WHL001:00900123#PWD121212#WHL001DErase the number in position 001 · reply WHL001-OK#ACM: access mode
ACM2 is secure access: only numbers on the white list activate the switch. ACM0 is open access: any call activates it. Open access is the default.
#PWD121212#ACM2Secure access on · reply ACM-ON#PWD121212#ACM0Secure access off, open access on · reply ACM-OFFWhat a call does
#GOT: relay time after a call
Sets how long each relay stays on when the switch is called. The maximum is 65,535 seconds. Five digits. Setting 00000 stops that relay switching on when the unit is called.
#PWD121212#GOT1=00900Relay 1 on for 15 minutes per call · reply GOT1:00900#PWD121212#GOT2=00600Relay 2 on for 10 minutes per call · reply GOT2:00600#PWD121212#GOT?Check both times and the delay · reply GOT1: 00900 GOT2: 00600 GOTS: 00005#GOTS: delay before relay 2
The delay, in seconds, before relay 2 switches on after a call. Setting 00000 prevents relay 2 switching on.
#PWD121212#GOTS=00005Relay 2 starts 5 seconds after the call · reply GOTS:00005Switching by text
#RLY: switch on for a time
Switches a relay on for up to 65,000 seconds this once, and sends texts when it switches on and off. It does not change the #GOT settings.
#PWD121212#RLY1=00060Relay 1 on for 60 seconds · reply RLY1=00060 then RELY1-OFF#PWD121212#RLY2=00005Relay 2 on for 5 seconds · reply RLY2=00005 then RELY2-OFF#RLOP: switch on or off
Switches a relay on until you switch it off. It does not change the #GOT settings. A 'RLOP1 Busy' reply means the relay is already active from an earlier command.
#PWD121212#RLOP1=1Relay 1 on · reply RLOP1=ON#PWD121212#RLOP1=0Relay 1 off · reply RLOP1=OFF then RELY1-OFF#PWD121212#RLOP2=1Relay 2 on (#RLOP2=0 switches it off) · reply RLOP2=ON#RLY?: relay status
Reports both relays: the time left on a timed switch and whether #RLOP has them on.
#PWD121212#RLY?Check the relays · reply RELAY1=00000 RELAY2=00000 RLOP1:OFF RLOP2:OFFReset
*REST#: back to factory settings
Resets the unit to its default settings. The #PWD prefix is not used: send *REST# followed by the current password. After REST-OK the password is 123456 again, and access mode, white list and times are back to their defaults.
*REST#121212Reset to defaults (password 121212) · reply REST-OKQuick reference
| Function | Command | Format | Note |
|---|---|---|---|
| Change the password | #CAP | #PWD123456#CAPxxxxxx#CAPxxxxxx | Default 123456 |
| Signal strength | #CSQ | #PWD123456#CSQ? | 0 to 31, must be 5 or more |
| Administrator list | #TEL | #PWD123456#TEL1=07700900123 | Up to 8 numbers, 16 digits |
| Administrator status | #RERN | #PWD123456#RERN10000000 | 1 = enabled, 0 = disabled |
| White list | #WHL | #PWD123456#WHL001=00900123 | Up to 500 numbers, last 8 digits |
| Access mode | #ACM | #PWD123456#ACM2 / #ACM0 | Secure on / off |
| Relay time on a call | #GOT | #PWD123456#GOT1=00900 | Maximum 65,535 seconds |
| Delay before relay 2 | #GOTS | #PWD123456#GOTS=00005 | 00000 stops relay 2 |
| Switch on for a time | #RLY | #PWD123456#RLY1=00060 | Maximum 65,000 seconds |
| Switch on or off | #RLOP | #PWD123456#RLOP1=1 | 1 = on, 0 = off |
| Reset | *REST# | *REST#123456 | No #PWD prefix |