Water where you are not
Fields, allotments, stock troughs and wells are rarely next to the house. A GSM switch at the pump means one call starts a watering cycle, and the relay timer ends it, so a forgotten pump does not run all night.
Text commands add the cases a fixed timer cannot cover. Rain at the farm, a burst pipe, a tank that needs topping up after a hot day: switch the pump on or off by SMS and get the confirmation back.
Use a contactor for the pump motor
Pump motors draw a large current when they start, often several times their running current. Do not switch a pump motor directly through the switch's relay contacts. Let the relay switch the coil of a contactor or motor starter that is rated for the pump, and let the contactor switch the motor.
Many irrigation controllers and pump control panels already have a remote start or external enable input. In that case wire the relay's NO and C terminals to that input, and the panel's own protections stay in charge.
Safety. If you are unsure how to connect the device you wish to control, refer to a qualified person.
Example settings
#PWD121212#WHL001=00900123Your number on the white list · reply WHL001:00900123#PWD121212#ACM2Secure access · reply ACM-ON#PWD121212#GOT1=00900Pump runs 15 minutes per call · reply GOT1:00900#PWD121212#RLY1=03600Once only: run it for 1 hour · reply RLY1=03600#PWD121212#RLOP1=0Stop the pump now · reply RLOP1=OFFTwo zones, one call
Two relays can run two valves or two pumps one after the other. Set #GOT1 for the first zone, #GOT2 for the second and #GOTS for the delay before relay 2 starts. Choose a delay at least as long as zone 1 runs if the water supply cannot feed both zones at once.
Remember that the relays are on/off contacts. The switch does not measure flow, pressure or tank level. If dry running would damage the pump, keep its own dry-run or float protection in the circuit.
Outdoor installation
- The GSM-AUTO enclosure is IP65 and rated for -20 to +55 °C, but the 12 V supply and contactor need their own weatherproof box
- Pump houses with concrete or metal walls weaken signal; check #CSQ? at the mounting spot
- Keep the 12 V supply on its own circuit, not from the pump panel, so a motor start cannot reset the switch
Questions
Can I see whether the pump is running?
Send #PWD121212#RLY? and the switch reports the relay times and whether each relay is on. It reports the relay, not the pump itself.
Can a call stop the pump?
A call starts the preset time; it does not stop it. Stop it early by text with #RLOP1=0.
What if the signal at the well is too weak?
Fit an external GSM antenna to the SMA socket and mount it higher or outside the pump house.