GSM-AUTO owners Manual (PDF) Help Contact
Use

Irrigation, well pumps and pumping stations by phone

Control irrigation systems, water well pumps and pumping stations from anywhere: switch on for a pre-set time with a call, or on and off as needed by text message.

Pump contactor coil switched by relay 1, terminals 7 (NO) and 8 (C)1+2-3C4NC5NO6NC7NO8C12 V DCRELAY 2RELAY 1CONTACTOR COILsupplysupplyNO
Pump contactor coil switched by relay 1, terminals 7 (NO) and 8 (C). Relays drawn at rest (off).

Water where you are not

Fields, allotments, stock troughs and wells are rarely next to the house. A GSM switch at the pump means one call starts a watering cycle, and the relay timer ends it, so a forgotten pump does not run all night.

Text commands add the cases a fixed timer cannot cover. Rain at the farm, a burst pipe, a tank that needs topping up after a hot day: switch the pump on or off by SMS and get the confirmation back.

Use a contactor for the pump motor

Pump motors draw a large current when they start, often several times their running current. Do not switch a pump motor directly through the switch's relay contacts. Let the relay switch the coil of a contactor or motor starter that is rated for the pump, and let the contactor switch the motor.

Many irrigation controllers and pump control panels already have a remote start or external enable input. In that case wire the relay's NO and C terminals to that input, and the panel's own protections stay in charge.

Safety. If you are unsure how to connect the device you wish to control, refer to a qualified person.

Example settings

#PWD121212#WHL001=00900123Your number on the white list · reply WHL001:00900123
#PWD121212#ACM2Secure access · reply ACM-ON
#PWD121212#GOT1=00900Pump runs 15 minutes per call · reply GOT1:00900
#PWD121212#RLY1=03600Once only: run it for 1 hour · reply RLY1=03600
#PWD121212#RLOP1=0Stop the pump now · reply RLOP1=OFF

Two zones, one call

Two relays can run two valves or two pumps one after the other. Set #GOT1 for the first zone, #GOT2 for the second and #GOTS for the delay before relay 2 starts. Choose a delay at least as long as zone 1 runs if the water supply cannot feed both zones at once.

Remember that the relays are on/off contacts. The switch does not measure flow, pressure or tank level. If dry running would damage the pump, keep its own dry-run or float protection in the circuit.

Outdoor installation

  • The GSM-AUTO enclosure is IP65 and rated for -20 to +55 °C, but the 12 V supply and contactor need their own weatherproof box
  • Pump houses with concrete or metal walls weaken signal; check #CSQ? at the mounting spot
  • Keep the 12 V supply on its own circuit, not from the pump panel, so a motor start cannot reset the switch

Questions

Can I see whether the pump is running?

Send #PWD121212#RLY? and the switch reports the relay times and whether each relay is on. It reports the relay, not the pump itself.

Can a call stop the pump?

A call starts the preset time; it does not stop it. Stop it early by text with #RLOP1=0.

What if the signal at the well is too weak?

Fit an external GSM antenna to the SMA socket and mount it higher or outside the pump house.