Wiring examples for a two-relay GSM switch

Eight terminals: two for 12 volts and three for each relay. Choose NO to switch something on while the relay is active, NC to switch it off.

The terminals

Note the order: relay 2 comes first on the terminal strip, and relay 1's common is terminal 8, at the end. Each relay is rated at 10 amps at 230 volts AC.

TerminalFunctionUsed for
1+12 V DCPower supply positive
20 V (-)Power supply negative
3Relay 2 CCommon contact of relay 2
4Relay 2 NCClosed when relay 2 is off
5Relay 2 NOClosed when relay 2 is on
6Relay 1 NCClosed when relay 1 is off
7Relay 1 NOClosed when relay 1 is on
8Relay 1 CCommon contact of relay 1

Heater and light

Heater on relay 2 (terminals 3 and 5) and light on relay 1 (terminals 7 and 8), both on the normally open contacts1+2-3C4NC5NO6NC7NO8C12 V DCRELAY 2RELAY 1HEATERsupplysupplyNOLIGHTsupplysupplyNO
Heater on relay 2 (terminals 3 and 5) and light on relay 1 (terminals 7 and 8), both on the normally open contacts. Relays drawn at rest (off).

A heater is connected to relay 2 and a light to relay 1. When the GSM-AUTO is activated the relay contact switches from the NC position to the NO position, making the circuit, and the heater and light are switched on.

The heater's supply runs through terminals 3 (C) and 5 (NO), the light's through terminals 8 (C) and 7 (NO). Each load keeps its own supply; the switch only opens and closes the contacts.

Main and backup server

Server 1 (main) on relay 1 normally closed contact, terminals 6 and 8; server 2 (backup) on relay 2 normally open contact, terminals 3 and 51+2-3C4NC5NO6NC7NO8C12 V DCRELAY 2RELAY 1SERVER 2supplysupplyNOSERVER 1supplysupplyNC
Server 1 (main) on relay 1 normally closed contact, terminals 6 and 8; server 2 (backup) on relay 2 normally open contact, terminals 3 and 5. Relays drawn at rest (off).

Server 1 (main) is connected to relay 1. When the GSM-AUTO is activated the relay contact switches from the NC position to the NO position, breaking the circuit and resetting the server.

Server 2 (backup) is connected to relay 2. When the GSM-AUTO is activated the relay contact switches from the NC position to the NO position, making the circuit and switching on the server.

Gate controller or heating programmer

Gate controller start push button terminals wired to relay 1, terminals 7 (NO) and 8 (C)1+2-3C4NC5NO6NC7NO8C12 V DCRELAY 2RELAY 1GATE STARTsupplysupplyNO
Gate controller start push button terminals wired to relay 1, terminals 7 (NO) and 8 (C). Relays drawn at rest (off).

Wire terminals 7 and 8 to the 'start' push button terminals of the gate control panel, or to the terminals of a heating programmer that switch it on. The relay contact then acts like the button or the programmer's switch.

Do not power the GSM-AUTO from the gate panel's auxiliary supply. Use a separate 12 volt supply.

Wiring rules

  • Power positive to terminal 1, negative to terminal 2; reversed, the red light stays off
  • Keep the relay contacts within 10 A at 230 V AC; put motors and big heaters on a contactor
  • Mains and 12 V wiring in separate cable entries, and mains only in a suitable enclosure
  • Program and test the switch before final installation

Safety. If you are unsure how to connect the device you wish to control, refer to a qualified person.